Article 210 52 a 1 of the nec states that a receptacle outlet must be installed in every kitchen family room dining room living room den bedroom or recreation room so that no point along.
Outlet spacing code. These general guidelines will give you the basics of what electrical inspectors are looking for when they review both remodeling projects and new installations. Nec 210 52 general circuitry kitchen a receptacle outlet shall be installed at each counter space 300 mm 12 inches or wider and at each island counter or peninsular space 600 mm 24 inches by 300 mm 12 inches or larger. 16 to top of box common install height above floor but see 18 below. Countertop spaces separated by range tops sinks or refrigerators are separate spaces.
Any countertop space 12 in. Any countertop 12 inches wider or more should have an outlet on the wall behind the countertop. In kitchens electrical outlets should be placed no farther than 48 inches apart so that no point on the countertop is more than 24 inches away from a receptacle. Electrical codes are in place to protect you the homeowner.
There are more specific code provisions for peninsulas islands behind sinks and receptacles below the countertop. The code requires that we have an electrical receptacle outlet no more than 6 feet from the corner of the wall and no more than 6 feet from an obstruction the doorway. Receptacles must be installed so that no point measured horizontally along the floor line in any wall space is more than 6 feet or 1 8 meters from an outlet in that space. The united states national electrical code section 210 52 states that a receptacle outlet must be placed in every kitchen bedroom living room family room and any other area designated has habitable space.
To meet code requirements we have placed an electrical receptacle outlet in the center of both of the walls that abut the doorway 2 feet from the door in both directions and 2 feet from the wall on both directions. They are all based on the same concept of probability of countertop use and common appliance cord length. 9 low side reach minimum height above floor for ada. 14 to center of receptacle above floor in canada higher allowed.
Or longer must have a receptacle with spacing of subsequent receptacles a maximum of 48 in. Although the code spells out requirements for the minimum number of receptacles in a dwelling it does not limit the number of receptacle outlets. 15 minimum receptacle height to bottom of outlet box california. No point measured along the floor line can exceed 6 feet from an electrical outlet to reduce the need for hazardous extension cords.